One building, two shifts
The hotel has
two shifts.
Scroll through a guest’s day, from 3:00 PM to 11:00 AM, and watch what the building does behind the walls. A typical mid-rise hotel, drawn to explain the systems; it is not any project’s plans.
- Check-in
- Dinner
- Swim and shower
- Overnight
- Early morning
- Check-out
3:00 PM3:00 PM to 11:00 AMCheck-inDinnerSwim and showerOvernightEarly morningCheck-out
Cutaway of a typical hotel followed through a guest’s day. Guest rooms have terminal units and a supplied corridor; the restaurant kitchen has a hood, exhaust fan and make-up air unit; a pool hall has a dehumidifier and a basement plant supplies hot water; sprinklers, a generator and a transfer switch cover the night; the laundry vents its dryers outside; and a loading dock takes deliveries.Corridor make-up airGuest-room terminal unitMake-up air unitKitchen exhaust fanHood suppressionPool dehumidifierHot water riserHot water plantSprinklersBack-up generatorTransfer switchSprinkler service entryDryer exhaustLoading dock
- Air
- Hot water
- Sprinklers
- Back-up power
3:00 PM Check-in
The room is ready before the key is cut.
- The guest
- A key, a lift, and a room that already feels right.
- The building
- Terminal units hold every room; corridors are supplied with fresh air.
Check-in is the end of a long preparation. A terminal unit holds the room at a comfortable temperature, the corridor is supplied with tempered outside air, and the lights come on in a space that already feels right. Rooms repeat by the dozen, so one sound decision is multiplied across every floor.
- Guest-room heating and cooling
- Corridor ventilation
- Controls the operator can run
In Chilliwack, a 60-suite TownePlace Suites and a 90-room Fairfield Inn share one six-storey building. Design Works provided mechanical and electrical engineering, fire protection and energy modelling. Fairfield Inn & TownePlace Suites by Marriott Chilliwack ↗
6:30 PM Dinner
Dinner is a ventilation problem.
- The guest
- A table, a menu and a warm dining room.
- The building
- The hood fan removes the cooking; make-up air replaces what it takes.
Over the cooking line a hood captures heat, grease and smoke, and a fan carries it out through the roof. Whatever that fan removes has to come back as make-up air, or the dining room starts to pull doors open. Hood, exhaust, make-up air, kitchen plumbing and fire suppression are designed as one set.
- Hood exhaust
- Make-up air
- Kitchen plumbing
- Hood fire suppression
For The Keg in Grande Prairie, our mechanical engineers designed heating, ventilation and air conditioning, kitchen exhaust and supply air, and plumbing for the commercial kitchen and dining areas. The Keg Steakhouse + Bar – Grande Prairie ↗
9:00 PM Swim and shower
A pool never stops evaporating.
- The guest
- A swim, then a long hot shower.
- The building
- The pool hall stays dry; the hot water plant meets the evening peak.
Pool water puts moisture into the air all day. A dedicated dehumidification unit keeps the hall dry, so humidity does not condense on glass or soak into the roof, while the hot water plant in the basement meets the evening shower peak through a recirculating loop.
- Pool hall dehumidification
- Domestic hot water plant
- Recirculation loop
Home2 Suites in Thunder Bay combines 90 suites, an indoor pool, a fitness centre and EV charging stations. The engineering focused on energy-efficient mechanical and electrical systems for 24/7 operation. Home2 Suites by Hilton Thunder Bay ↗
11:30 PM Overnight
The quiet hours are when it matters.
- The guest
- Lights out, and a quiet night.
- The building
- Sprinklers, alarm and exit lighting stay on duty; the generator stands ready.
With the guests asleep, the sprinklers are on duty on every floor, alarm devices watch the corridors and exit lighting stays on. If the grid drops, a generator and transfer switch carry the life-safety loads. Life safety is designed with the building, then tested until the owner trusts it.
- Sprinklers
- Fire alarm and exit lighting
- Back-up power and transfer switch
At the six-storey Prince Arthur Hotel in Thunder Bay, built in 1911, the renovation replaces the mechanical, electrical and fire protection systems while keeping the building’s historic features. Prince Arthur Thunder Bay ↗
6:00 AM Early morning
The laundry has already started.
- The guest
- Coffee, and clean towels.
- The building
- The laundry runs hot and wet; dryers exhaust outside.
Towels and linens are a daily industrial process. Washers need hot water and drains, dryers need a path to outside, and the room needs the air it exhausts. These loads are easy to forget in a design and hard to fix once the walls are closed.
- Laundry hot water and drains
- Dryer exhaust
- Make-up air
- Space and access
The Best Western Plus planned for Devon, Alberta puts suites with kitchens, banquet and meeting rooms, a pool and a hot tub under one roof. Each adds its own load to the plant. Best Western PLUS ↗
11:00 AM Check-out
Check-out, and the day starts again.
- The guest
- A last look at the lobby.
- The building
- The dock takes deliveries; rooms reset to their overnight setback.
The dock takes the morning’s deliveries, the rooms reset and the building returns to its overnight setback until the next arrival. Hotels are renovated, rebranded and expanded within the same shell, so the plant, the shafts and the structure should leave room for the next decision.
- Deliveries and access
- Setback and controls
- Room for expansion
In Penticton, the 1960s Skiers Motel Hotel grew from 36 to 88 rooms and reopened in 2026 as a Comfort Inn & Suites. Design Works provided structural, mechanical and electrical engineering, energy modelling and fire protection. Comfort Inn & Suites Penticton ↗