Engineering for cold
One building.
Six northern problems.
Scroll through a northern building from the ground up, and the decisions that keep it standing, warm and running.
- Ground
- Air
- Water
- Power
- Upkeep
- Season
Section through a northern building raised on piles above permafrost: a geotechnical borehole beside the site, the building lifted off the ground so its warm floor cannot thaw the soil, a ventilated crawlspace, heat-recovery ventilation with frost protection, holding tanks filled and emptied by truck through heat-traced lines, power from a local generating plant with standby power, service access around the equipment, and prefabricated modules joined on site in the short building season.Active layerPermafrostGeotechnical boreholeThawed groundLifted on pilesVentilated crawlspaceHeat recovery ventilationFrost protectionHolding tanksHeat-traced lineFill and pump-outTruck accessLocal generating plantStandby powerMaintenance accessClear controlsPrefabricated modulesModule jointShort building season
- Outdoor air
- Warm air & heat trace
- Water
- Power
- Service access
Start with the ground
On permafrost, a warm building can thaw the ground beneath it. Structures are often lifted off the ground on piles or adjustable foundations, with ventilated space below. We design the structure with the geotechnical engineer’s site-specific recommendations—never assumptions borrowed from another region.
- Geotechnical input
- Piles or adjustable foundations
- Ventilated crawlspace
Keep the cold out
Ventilation at −40 needs heat recovery that won’t freeze up, controls that fail safe and air paths that keep the building dry. We size the mechanical systems on location-specific design conditions, using envelope information from the architect and envelope consultant.
- Heat recovery ventilation
- Frost protection
- Cold-climate design conditions
Water that can’t freeze
Many northern communities rely on trucked water and sewage, with holding tanks inside the building. Every pipe that crosses the envelope is insulated, heat-traced or routed to stay warm, with the fill and pump-out points where the truck can reach them.
- Holding tanks
- Heat-traced lines
- Truck access
Power you can count on
Many remote communities are powered by local diesel generation with limited spare capacity. Efficient loads, careful capacity checks with the utility and dependable standby arrangements matter more here than anywhere.
- Load and capacity review
- Standby power
- Efficient systems
Systems the community can run
The best northern system is one the local operator can maintain. We favour access, common parts and controls that can be understood on site, and we plan for spare parts and training with the owner.
- Maintenance access
- Common parts
- Clear controls
Build in the window
Short seasons and limited shipping make prefabrication valuable. Modules or panels built in the south can arrive ready to set, cutting the work done on site.
Five modular classrooms for Yellowknife were fabricated off site and installed with minimal disruption to the school. NWT Modular Classrooms ↗